Add/Copy Alarm Generation Settings
Follow these rules to configure Trap to Alarm rules:
- Set whether to select the Keywords:
If it is selected, you can perform the following operations:
- Configure the list of keywords that indicates the keywords in trap description.
- Select Keyword (Yes or No) to configure whether to include or exclude the keywords
- Select Logical Combination (AND or OR) to set the AND/OR relationship between the keywords.
You can specify multiple keywords at a time. The relationship between multiple keywords can be AND or OR, but cannot be a combination of AND and OR. The total number of characters of all the keywords cannot exceed 256.
- Set whether to enable the Trap Source option. When the option is enabled, configure the following parameters:
- From the If Match list, select Yes or No to include or exclude trap sources.
- Select devices or application groups as trap sources.
- Set whether to select the Trap Type option:
If it is selected, you can perform the following operations:
- Configure a list of trap types
- Select If Match (Yes or No) to configure whether to include or exclude these trap types, and configure parameters for the selected traps.
- Set whether to select the Time Range:
If it is selected, you can configure a periodic time range or an absolute time range.
- A match rule includes at most the following items that are matched in descending order of priority:
- Keywords
- Trap source
- Trap type (including trap parameters)
- Time range
The relationship between these items is AND.
Operation Procedure
- Type the match rule name (available only when adding a rule) and rule description.
- Select the keywords, trap source, trap type, and time range, and then you can configure the corresponding sub-items.
- Click OK.
Precautions
- Application groups are supported only if the APM component is installed.